Summer is coming soon, and as air temperature and humidity rise, compressed air systems will be subjected to more water loads during air handling. The summer air is more humid, with 650% more moisture in the air at the highest compressor operating conditions in summer (50°) than in the normal maximum temperature in winter (15°). As the temperature rises, the working environment of the air compressor becomes more severe. Improper handling can cause serious high-temperature trips and even coking of the lubricating oil. So preparing your air compressor for the toughest of the year is a must!
Take the following quick and easy steps to ensure that the Kaishan compressed air system will survive the summer safely:
1. Check ventilation and oil filter
In summer, the air filter and the oil filter are two-pronged. It is very important to check the compressor room and adjust the ventilation and air volume as needed. This is also a good time to check for pollen and other air pollutants that are prevalent in the spring to make sure your ventilation is clean before the summer heat sets in.
The blockage of the oil filter will cause the lubricating oil to not cool the heat generated by the compressed air in time, and will also cause the rotor to not be lubricated and cooled in time, resulting in greater economic losses.
2. Regularly replace the Kaishan air filter
A clean air filter will reduce the operating temperature of the air compressor and reduce energy consumption. Dirty, clogged filters cause a pressure drop, which causes the compressor to run at a higher level to meet demand. Filter performance can also be affected by extra moisture, so be sure to follow a regular 4000h maintenance schedule and add seasonal checks.
3. Clean the cooler
The blockage of the cooler will make it difficult for the Kaishan air compressor to dissipate heat, resulting in high temperature in hot summer, so the cooler must be kept clean and cleaned regularly.
4. Check the sewer
Higher humidity in summer will cause more condensation to drain down the drain. Make sure the drains are unobstructed and in working order so they can handle the increased condensation. When the rotor outlet temperature is lower than 75°, it may cause high-temperature and high-humidity gas to precipitate condensed water during compression. At this point, the condensed water will mix with the lubricating oil, causing the oil to emulsify. Therefore, the water should be treated before it is discharged directly to the sewer. Check the treatment unit’s filter and separator tank to make sure they are still functioning.
5. Adjust the water cooling system
In addition, the water-cooled air compressor used can adjust the temperature of the water entering the cooling system to compensate for the increase in ambient temperature and ensure that it is suitable for summer conditions.
Through the above methods, you can be assured of the effective operation of the air compressor. If you have any questions about Kaishan air compressor machinery purchase, maintenance, after-sales, repair, energy-saving renovation, please contact us. At the same time, we provide you with flexible cooperation modes, payment methods, delivery processes, and after-sales services.
Post time: May-25-2023